AC UPS Solutions

Commercial UPS (Helios Series)

5–200 kVA power ratings

Online double conversion topology

N+1 redundancy

I/O: 1Ø–1Ø, 3Ø–3Ø, 3Ø–1Ø, 1Ø–3Ø

Battery: VRLA, Li-Ion, NiCd

Nominal Ratings

SpecificationDetails
Power Range5 kVA – 200 kVA
TopologyOnline double conversion
Parallel RedundancyN+1 configurable
I/O Combinations1Ø–1Ø, 3Ø–3Ø, 3Ø–1Ø, 1Ø–3Ø

Input (Rectifier Section)

SpecificationDetails
Nominal Voltage230V / 415V AC, 3-Phase, 4 Wire
Nominal Frequency50/60Hz
Input Power Factor0.99
Input Harmonics (THDi)<4% at full linear load

Battery

TypeSupported Models
Internal BatteryVRLA, Li-Ion
External BatteryVRLA, Li-Ion

Output (Inverter Section)

SpecificationDetails
Nominal Voltage230V / 415V AC, 3-Phase
Frequency50/60Hz
Voltage Harmonic Distortion<2% (linear), <5% (non-linear)
Overload Capacity100–110%: 60 min
125%: 10 min
150%: 1 min
Crest Factor3:1
Efficiency≥90% (double conversion)

Static Bypass Section

SpecificationDetails
TypeFully static, IGBT-based
Transfer Time≤4 ms (online), ≤0 ms (double conversion)
Bypass Voltage Range±15%
Overload Capability125% (10 min), 150% (1 min), 1000% (1 cycle, fault clearing)
Auto Re-transferSupported

Environmental & Mechanical

SpecificationDetails
Operating Temperature0–50°C (derating above 40°C)
Storage Temperature-20°C to +70°C
Relative Humidity0–95% (non-condensing)
Altitude≤1000m (without derating), up to 3000m (with derating)
CoolingForced air with redundant fans
Enclosure ProtectionIP20 standard, IP31 optional
ComplianceIEC 62040-1/2/3

Communication & Monitoring

CategoryDetails
DisplayLCD panel with real-time monitoring of input, output & battery parameters
PortsRS232, RS485, MODBUS, USB, SNMP (optional)
Remote MonitoringSNMP supported
Alarm IndicationsAudible & visual alarms for warnings and faults

Noise & Dimensions

SpecificationDetails
Noise (at 1m)<70 dB
Dimensions & WeightStandard per rating

Helios Series – Smarter Power, Continuous Protection
At Chhabi Electricals, we understand that your business success depends on operational continuity and efficiency. Downtime isn’t an option, and energy costs must be controlled. The Helios Series is designed to safeguard sensitive commercial and IT environments with reliable, disturbance-free power. With its online double conversion technology, intelligent monitoring, and compact design, it delivers the stable, adaptable, and efficient AC power your mission-critical applications require.

Uninterrupted Power for Every Application

High Efficiency Operation

>90% efficiency with IGBT-based rectifier & inverter.

Compact Design

Optimized footprint for server rooms and commercial spaces.

Digital Precision

DSP-based regulation ensures stable power and fast response.

Advanced Battery Management

Supports VRLA, Li-Ion, NiCd with intelligent charging.

Comprehensive Protection

Safeguards against overload, short circuit, overtemperature, and disturbances.

Industries We Serve

Power Generation & Utilities

 Reliable DC power for control, protection, and backup across thermal, nuclear, hydro, renewable plants, and utility operations.

Heavy & Resource Industries

Rugged DC systems designed to perform in demanding environments like cement, mining, metal, and steel plants.

Energy & Infrastructure

Mission-critical power solutions for oil & gas, petrochemicals, and pipelines operating in hazardous and remote zones.

Critical Infrastructure & Data

High-availability DC power for data centers, railways, and defense applications where downtime is not an option.

FAQ

Frequently Asked Questions - Commercial UPS

Q1. What is a UPS power supply and how does it support daily operations?

A UPS power supply ensures that connected systems continue to run without interruption during power cuts. It acts as an instant backup, avoiding sudden shutdowns that can affect work and data.

A reliable power backup solution keeps systems running during outages and protects sensitive equipment. It also helps avoid productivity loss caused by unexpected downtime.

Reliability comes from its ability to deliver consistent output even when input power is unstable. A well-designed UPS isolates equipment from fluctuations and keeps performance steady.

Performance depends on system capacity, battery condition, and load handling ability. Proper configuration plays a big role in ensuring smooth operation.

Yes, they are designed to manage frequent voltage changes without affecting output. This makes them useful in areas with unstable power supply.

DC UPS suppliers assist in selecting the right system, proper configuration, and smooth installation. Chhabi Electricals focuses on delivering solutions that integrate well and perform reliably in actual operating environments.

The right choice depends on load size, backup requirement, and application type. Proper evaluation helps in selecting a system that performs reliably over time. Chhabi Electricals' team can guide you in selecting the right Helios Series UPS for your commercial or IT setup.

Reliable backup solutions reduce downtime, protect equipment, and improve efficiency. Over time, this results in better productivity and lower risk.

They prevent sudden shutdowns that can damage equipment or disrupt processes. This improves overall system safety and reliability.

Frequent load changes can impact how a UPS power supply responds to demand, especially in dynamic environments. A well-designed system from Chhabi Electricals adjusts output in real time, ensuring stable performance without voltage drops or stress on connected equipment.