DC UPS Solutions

Digital Charger (Agile Alpha Series)

24–360 VDC

Up to 3000 A

DSP-based closed-loop control

Lead-acid • VRLA • Ni-Cd • Li-ion

Thyristor Battery Chargers – Uninterrupted Power, Unmatched Reliability

At Chhabi Electricals, we recognize that your operations demand unwavering power continuity. That’s why our DC UPS solutions are engineered to deliver reliability, precision, and intelligent control—ensuring your business never skips a beat. Whether you need rugged simplicity or smart, adaptive power management, we have the right solution tailored to your needs.

Uninterrupted Power for Every Application

Precision Control

DSP/microcontroller closed-loop control ensures ±1% regulation accuracy.

Predictive Diagnostics

Monitors 25+ parameters (ripple, harmonics, battery impedance).

Intuitive HMI

7-inch LCD/touchscreen for live data, alarms, and mode visualization.

Adaptive Charging

Auto-switches between Float/Boost/Equalize with temperature compensation.

Seamless Integration

Supports Modbus RS-485, RS-232, TCP/IP, Profibus; remote read/write facility

Electrical

Specification Details
Input AC Supply 415 V AC ±10%, 3 Phase, 3/4 Wire, 50Hz or 60Hz ±5% or 230 V AC ±10%
DC Output Voltages 24V, 48V, 110V, 125V, 220V, 360V
DC Output Current Range 5A – 3000A (other ratings on request)
Applicable Standards IS 4540, IEC 146 (as applicable)
Quality Standards ISO 9001, ISO 14001, ISO 45001, ZED (Zero Defects Zero Effects)
Supported Battery Types Lead Acid, VRLA, Nickel Cadmium, Li-Ion
Charging Characteristics Constant Current – Constant Voltage (CC-CV)
Cell Configuration 24V, 48V, 110V, 125V, 220V, 360V
DC Output Voltage – Float Mode LA: 2.15–2.20 VPC
VRLA: 2.15–2.25 VPC
Ni-Cd: 1.40–1.42 VPC
DC Output Voltage – Boost Mode LA: 2.65–2.75 VPC
VRLA: 2.30–2.35 VPC
Ni-Cd: 1.65–1.70 VPC
Voltage Regulation ±1% (0–100% load, float mode)
Current Variation Adjustable 10%–100% (boost mode)
Current Limit 105% of rated current (float mode)
DC Current Regulation ±2% (boost mode)
Magnetics Isolation Transformer / Filter Choke
Insulation Class Class F, Temperature rise 90°C (for magnetics)
High Voltage Withstand 2.5 kV for 1 minute
Rectifier Type Fully Controlled Bridge (6 / 12 / 24 Pulse Thyristor)
Output Ripple ≤1% RMS / 2% RMS / 3% RMS or Peak-to-Peak (without battery connected)
Efficiency ≥80% at full load (110V, 220V, 360V models)
≥70% at full load (24V, 48V models)

Instrumentation

CategoryDetails
OutputDC Voltmeter, DC Ammeter
BatteryDC Voltmeter, DC Ammeter
InputAC Voltmeter, AC Ammeter (optional)
DisplayThrough LCD / Touchscreen

Protection Features

Protection FeatureDetails
Thyristor Protection FuseProvides safety for thyristors against faults
Soft StartPrevents inrush currents during startup
Electronic Current LimitRestricts current to safe operating levels
Phase ProtectionPhase sequence reversal & phase failure protection

Alarms & Indications

CategoryDetails
Alarms / Annunciations
  • LED Annunciations
  • Window Annunciation
  • Digital & Analog combined Annunciations (DAA – Chhabi make)
Status IndicationsRelay Contacts: Potential free (optional)
CommunicationRS485 (optional)

Mechanical

SpecificationDetails
ConstructionFolded sheet MS, powder coated (Paint Shade – Customizable)
Sheet ThicknessFrame (Load bearing members) – 2 mm, Panels (Non-load bearing members) – 1.6 mm
Cable EntryBottom (top on request)
Panel AccessFront & rear; Only front on request
Terminal ArrangementBack side
Enclosure ProtectionIP20 / IP31 / IP42 (others i.e. IP5x on request)
CoolingNatural air cooling / Forced air cooling
Noise Level70 dBA (natural) / 80 dBA (forced cooling)
InstallationIndoor, floor mounting, self-standing

Operating Conditions

ConditionDetails
Temperature0°C to +50°C
Humidity≤95% RH (non-condensing)
Altitude≤1000m above MSL

Industries We Serve

Power Generation & Utilities

 Reliable DC power for control, protection, and backup across thermal, nuclear, hydro, renewable plants, and utility operations.

Heavy & Resource Industries

Rugged DC systems designed to perform in demanding environments like cement, mining, metal, and steel plants.

Energy & Infrastructure

Mission-critical power solutions for oil & gas, petrochemicals, and pipelines operating in hazardous and remote zones.

Critical Infrastructure & Data

High-availability DC power for data centers, railways, and defense applications where downtime is not an option.

Talk to an Engineer

Share voltage, current, duty cycle, battery type, and environment.

Book a Call Now